Back To Top
Flexim FLUXUS H831 Hydrocarbon Meter for Standard Volume Flow in Hazardous Areas
Flexim FLUXUS H831 Hazardous Area Hydrocarbon Meter for Standard Volume Flow
The Flexim FLUXUS H831 is the ATEX/IECEx Zone 1 and FM C1D1 hazardous area rated flow and analytical measuring system for the hydrocarbon processing industry (HPI).
This sophisticated and highly accurate non-intrusive flow meter combines very precise ultrasonic flow and sound speed measurement, advanced calculation features and diagnostics with a robust, durable and industry minded "fit for purpose" explosion/flameproof housing. The H831 non-intrusive flow meter’s built-in HPI computer calculates API gravity, operational density, density at base conditions and kinematic viscosity. Volumetric flow rates reported by the meter are automatically compensated for live temperature and pressure inputs according to industry standards ASTM1250, GPA TP25, D4311 and ISO 91.
Flexim FLUXUS H831 Hydrocarbon Meter for Standard Volume Flow in Hazardous Areas

Specs

Accuracy
Measurement uncertainty of the measuring system (volumetric flow rate): ±0.3 % of reading ±0,005 m/s (±0.02 ft/s)
Measurement uncertainty at the measuring point (volumetric flow rate): ± 1…2 % of reading ±0,005 m/s (±0.02 ft/s)
Certifications/Approvals
FM Class I/Div. 1
FM Class 1/Div. 2
ATEX/IECEx Zone 1
INMETRO
NEPSI
PESO
KOSHA
Communication Protocol
Modbus RTU
BACnet MSTP
Profibus PA (optional Ex-ia)
Foundation Fieldbus (optional Ex-ia)
Flow channels
up to 2
Fluid Type
Various hydrocarbons
Input
Temperature (optional Ex-ia)
4..20mA (optional Ex-ia active)
Output
4-20mA active/passive (optional Ex-ia)
4-20mA HART active/passive (optional Ex-ia)
pulse/frequency/binary
Pipe size
6 to 6500 mm (0.24 to 255.9 inch)
Power supply
100-230VAC
20-32VDC
Pressure range
-
Range
Flow Velocity Range: 0,01 to 25 m/s (0.03 to 82 ft/s), depending on pipe diameter
Repeatability
0.15 % of reading ±0,005 m/s (±0.02 ft/s)
System configuration and installation
For more detailed Information please download the Technical Specifications
Temperature range (media)
-40 to +240°C (-40 to +464°F) / WI: -200 to +630°C (-328 to +1166°F)

Features

  • Fit for purpose: process inputs (pressure and temperature) enabled for hydrocarbon processing applications and standard flow reporting according to industry standards ASTM1250, GPA TP25, D4311 and ISO 91.
  • Highly cost-effective: no pipe work, no process shut-down, virtually maintenance-free.
  • Matched, paired and wet calibrated flow transducers (traceable certification to national standards).
  • Excellent zero-point stability and drift-free.
  • Wide turndown ratio.
  • Independent of pipe size, material, operating pressure, medium and temperature (from as low as -200 to +630 °C / -328 to +1166 °F).
  • Free of wear and tear and abrasion.
  • Not prone to clogging or corrosion.
  • No pressure loss or risk of potential leaks and fugitive emissions.
  • Advanced Meter Verification.

Education

Interested in attending a training class?

Visit Course Listing