Back To Top
Flexim FLUXUS G70X SIL Functional Safety
Flexim FLUXUS G70X SIL G Functional Safety
The Flexim FLUXUS G70X SIL flow meter is an ideal choice when it comes to maintaining accurate measurements in harsh conditions - e.
g. during the flow measurement of highly pressurised, aggressive, toxic or highly explosive gaseous media. The SIL 2 certification of the G70X SIL non-intrusive flow meter includes the entire measuring system - the measuring transmitters and transducers.
Flexim FLUXUS G70X SIL Functional Safety

Specs

Accuracy
Measurement uncertainty of the measuring system (volumetric flow rate): ±0.5 % of reading ±0,01 m/s (±0.03 ft/s)
Measurement uncertainty at the measuring point (volumetric flow rate): ±1…3 % of reading ±0,01 m/s (±0.03 ft/s)
Certifications/Approvals
FM Class I /Div 2
ATEX/IECEx Zone 2
NEPSI
PESO
KOSHA
Communication Protocol
RS232
Flow Channels
up to 2
Fluid type
All gases
Input
-
Output
4-20mA active/passive
binary
Pipe size
7 to 1600 mm (0.28 to 63 inch)
Power supply
100-230VAC
Pressure range
1barg (15 psig) to unlimited
Range
Flow Velocity Range: 0,01…35 m/s (0.03 to 115 ft/s), depending on pipe diameter
Repeatability
0.15 % of reading ±0,01 m/s (±0.03 ft/s)
Temperature range (media)
-40 to +240°C (-40 to +464°F)

Features

  • Simple retrofitting during ongoing operation.
    Ideal for a subsequent increase in safety.
    Ideal for maintaining the protective function should an inline measurement fail.
  • Comprehensive certification.
    Transducers, clamp device and electronics are part of the FMEDA.
  • Extremely wide range of applications.
    Transducers and measuring transmitters for the flow measurement of gases.
  • Straightforward retesting.
    Easy functional tests in no time at all.
    Convincing self-diagnosis functions.
  • Transparent evaluations.
    Publication of FMEDA report.
    Full information on certification procedures and scope.

Education

Interested in attending a training class?

Visit Course Listing