Back To Top
Micro Motion™ 9739MVD Field And Truck Mount Multivariable Transmitter (Obsolete)
Micro Motion 9739 Transmitter kit
This product is now obsolete.


Please contact your local Emerson representative for your measurement needs.

Micro Motion Coriolis Meter Characterization and Configuration Using the Transmitter Display

Play Video

Characterize and Configure a Micro Motion Coriolis Meter

Play Video
Micro Motion™ 9739MVD Field And Truck Mount Multivariable Transmitter (Obsolete)

Specs

Output variables
Mass & volume flow
Temperature
Density
Pressure
Concentration
API average density
Local display
Standard user interface with 2-line LCD panel
Two optical switches for local operation
Two clips for service port connections (requires removing transmitter housing cover)
Two clips for HART/Bell 202 connections (requires removing transmitter housing cover)
HART security switch (requires removing transmitter housing cover)
Glass lens
Communication
Bell 202
RS-485
Power
Self-switching AC/DC input, automatically recognizes supply voltage
85 to 250 VAC, 48 to 62 Hz, 10 watts typical, 15 watts maximum
12 to 30 VDC, 7 watts typical, 14 watts maximum
Complies with low voltage directive 2006/95/EC per EN 61010-1 (IEC 61010-1) with amendment 2
Input/output signals
Not intrinsically safe
Two active mA outputs, configurable to 4–20 mA or 0–20 mA
One active/passive frequency/pulse output
One active/passive discrete output
One active discrete input
One sensor frequency output
One sensor temperature output
One mA input
Mounting options
Remotely mounted to any 9-wire Micro Motion Coriolis sensor.
Application types
Continuous process control
Custody transfer
Two-phase flow/entrained gas
Concentration measurement
Petroleum measurement
Hazardous approvals
UL and CSA C-US: Without display
Transmitter:
Class I, Div. 1 , Groups C and D
Class II, Div. 1, Groups E, F, and G explosion proof when installed with approved conduit seals or Class I, Div. 2, Groups A, B, C, and D
Outputs:
Class I, Div. 2, Groups A, B, C and D with nonincendive sensor outputs
Class 1, Div. 1, Groups C and D and Class II, Div. 1, Groups E, F, and G with instrinsically safe sensor outputs

UL and CSA C-US: With display
Transmitter:
Class I, Div. 1 , Groups A, B, C, and D
Outputs:
Class I, Div. 2, Groups A, B, C and D with nonincendive sensor outputs
Class 1, Div. 1, Groups C and D and Class II, Div. 1, Groups E, F, and G with instrinsically safe sensor outputs

ATEX: Without display
Flame-proof transmitter: II 2 G Ex d[ib] IIB/IIC T6 Gb
Safe-area transmitter: II 2 G [Ex ib Gb] IIB/IIC

ATEX: With display
II (2)G [Ex ib Gb] IIB/IIC