Viscosity accuracy
±0.2 cP (0.5 to10 cP) then ±1% of calibration range maximum (10 to 100 cP)
Operating viscosity range
0.5 to 100 cP
Density accuracy
±1.0 kg/m3(±0.001g/cm3)
Operating density range
0 to 3000 kg/m3(0 to 3g/cm3)
Operating temperature range
–50 °C to +200 °C (–58 °F to +392 °F)
Materials
• Wetted parts:316L stainless steel and Diamond-Like Carbon (DLC) • Tine finish:DLC coated • Transmitter housing:Polyurethane-painted aluminum
Local display (optional)
• Segmented two-line LCD screen. • Can be rotated on transmitter, in 90-degree increments, for ease of viewing. • Suitable for hazardous area operation. • Optical switch controls for hazardous area configuration and display. • Glass lens. • Three-color LED indicates meter and alert status.
Display functions
View process variables
View and acknowledge alerts
Configure mA and RS-485 outputs
Supports Known Density Verification (KDV)
Supports multiple languages
Transmitter output channels
Available output channels: • Channel A is 4–20 mA + HART • Channel B is 4–20 mA • Channel C is RS-485/Modbus
Meter approvals, calibrations, and certifications
Agencies & types of approval available: • CSA • IECEx • NEPSI • ATEX